10.2.2 Factory Default

If the access password is no longer
available, follow the procedure to reset to
default factory settings.
The effect of the Factory Default procedure is
the same as restoring the factory default settings
through the web interface (Hard Reset button).
To restore the factory settings relative to the
network, user access and camera configuration
follow this procedure:
• Switch off the unit.
• Open the connection compartment.
• Press and hold the reset button (P1, 6.3 Connector
board description, page 28).
• Power the unit.
• Wait 30 seconds.
• Release the reset button.
• Wait for 2 minutes.
• Switch off the unit.
• Close the connections compartment.
• Power the unit.
It is also possible to perform the reset in remote
mode. Follow the procedure below:
• Switch off the unit.
• Connect the RST contacts of connector J6 (6.3
Connector board description, page 28).
• Power the unit.
• Wait 30 seconds.
• Disconnect the RST contacts.
• Wait for 2 minutes.
• Switch off the unit.
• Power the unit.
Once the factory default procedure has
finished, you need to configure the unit
as described in chapter: 8.1 Default IP
address, page 34.
MNVCMPXHDC_2100_EN

11 Cleaning

Before carrying out any type of
maintenance, read the "Safety rules"
chapter carefully in the product manual.
Frequency will depend on the type of
environment in which the product is used.

11.1 Routine cleaning

11.1.1 Cleaning the glass window

Cleaning should be done with mild soap diluted
with water.

11.1.2 Cleaning the germanium window

When cleaning the window, take care not
to scratch or damage the outer surface
treated with carbon coating. Damage to
this coating could also interfere with the
transparency of the surface to infrared
light.
Cleaning should be done with mild soap diluted
with water.
Remove the protective grate and the spacer,
unscrewing the countersunk screws on the front of
the housing, using a 2mm spark-proof hexagonal
wrench.
Fig. 26
Once done cleaning, reassemble the spacer and the
protection grid.
Pay attention to the fixing. Tightening
torque: 1Nm.
37