MAXIMUS MPXL SERIES2 (CON VIDEOTEC ANALYTICS)- CERTIFICAZIONI E MARCATURE
Codice prodotto
Certificazione
MPXL1282GV**C,
ATEX
MPXL2282GV**C,
MPXL3282GV**C
IECEx
EAC Ex (in corso)
INMETRO
KCs
UL Hazardous
Location America
UL Hazardous
Location Canada
MPXL6282GV**C
ATEX
IECEx
EAC Ex (in corso)
INMETRO
KCs
Tab. 11
MAXMIUS MPXL SERIES2 (MPXL) con VIDEOTEC ANALYTICS
24
Marcatura
II 2G Ex db IIC T6...T4 Gb
II 2D Ex tb IIIC T85°C...T135°C Db
Ex db IIC T6...T4 Gb
Ex tb IIIC T85°C...T135°C Db
1 Ex d IIC T6...T4 Gb X
Ex tb IIIC T85°C...T135°C Db X
Ex db IIC T6...T4 Gb
Ex tb IIIC T85°C...T135°C Db
Ex db IIC T6...T4 Gb
Ex tb IIIC T85°C...T135°C Db
Class I, Zone 1, AEx db IIC T5...T4 Gb
Zone 21, AEx tb IIIC T100°C...T135°C Db
Class I, Div 2, Group A, B, C, D T5...T4
Class II, Div 2, Group F, G T5...T4
Ex db IIC T5...T4 Gb X
Ex tb IIIC T100°C...T135°C Db X
Class I, Div 2, Group A, B, C, D T5...T4
Class II, Div 2, Group F, G T5...T4
II 2G Ex db IIC T6...T4 Gb
II 2D Ex tb IIIC T85°C...T135°C Db
Ex db IIC T6...T4 Gb
Ex tb IIIC T85°C...T135°C Db
1 Ex d IIC T6...T4 Gb X
Ex tb IIIC T85°C...T135°C Db X
Ex db IIC T6...T4 Gb
Ex tb IIIC T85°C...T135°C Db
Ex db IIC T6...T4 Gb
Ex tb IIIC T85°C...T135°C Db
Temperatura ambiente
-40°C ≤ Ta ≤ +40°C or +50°C
or +60°C
(T6/T85°C con Ta ≤ +40°C)
(T5/T100°C con Ta ≤ +50°C)
(T4/T135°C con Ta ≤ +60°C)
-40°C ≤ Ta ≤ +40°C or +55°C
(T5/T100°C con Ta ≤ +40°C)
(T4/T135°C con Ta ≤ +55°C)
-40°C ≤ Ta ≤ +40°C or +50°C
or +60°C
(T6/T85°C con Ta ≤ +40°C)
(T5/T100°C con Ta ≤ +50°C)
(T4/T135°C con Ta ≤ +60°C)
MNVCMPXHDC_2100_IT
Temperatura di
ingresso dei cavi
+80°C