GB Setting of the end positions with setting switch
4.5.3. Manual setup-mode, deletion and manual setting of the end positions
in operation bottom position, top position
When the movement is interrupted once, the system is in manual setup-mode.
In manual setup-mode, the lower end position must be set and stored first. Afterwards,
the upper end position can be set and stored.
Operation
E
6 s
E
E
3 s
E
E
3 s
Drive
Press the E button of the setting switch for 6 seconds.
The motor will switch to manual setting mode. Both limit
positions already set will be deleted.
Move the motor to the lower end position with the UP or
DOWN button.
Press the E button for 3 seconds.
The correct rotation direction assignment will be carried out
at the end of the end position setting.
Move the motor to the designated upper end position.
Press the E button for 3 seconds.
The end positions are now set and the rotation direction
assignment is correct. Perform a test run.