Oil burner
TECHNICAL FEATURES
Thermal power – output
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
For use on hot air generator the burner must be fitted with control box type 539SE.
Burner with CE marking in conformity with EEC directives: EMC89/336/EEC, Low Voltage 73/23/EEC,
Machines 89/392/EEC and Efficiency 92/42/EEC.
The burner meets protection level of IP 40, EN 60529.
DIN Certification No. : 5G329 / 94 as EN 267.
8
4
3
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pump pressure regulator
5 – Vacuum gauge connection
6 – Screws fixing air-damper
7 – Hydraulic jack with air-damper
8 – Lock-out lamp and reset button
9 – Flange with insulating gasket
2340
G2
CODE
14.2 – 30 kW
Gas oil, max. viscosity at 20 ° C: 6 mm
Single phase, 230 V ± 10%
Run current 0.65 A – 2850 rpm – 298 rad/s
4 m F
Secondary 8 kV – 16 mA
Pressure 7 – 15 bar
0.165 kW
D5506
3742612
–
1.2 – 2.5 kg/h
~
Fig. 1
7
6
6
9
EQUIPMENT
Quantity
2
Flexible pipes with nipples
1
Flange with insulating gasket
2
Screws and nuts for flange
1
Screw with two nuts for flange
1
GB
426T1
TYPE
/s (1.5 ° E)
2
50Hz
2
1
Description
5