Cleaning the Dust Container and Filter
1. Press the handheld release button and remove the tube. [6]
2. Press the dust cup empty button to open the bin flap and empty it. [7]
3. Push down the battery pack release button and remove the battery pack. [8A,8B]
4. Turn the dust bin in a clockwise direction, align the arrow marks and remove from cleaner main body. [9]
5. Clean any excess dust from the mesh filter [K2], hold the mesh firmly with one hand and with the other turn the cover
cup [K3] in a clockwise direction to remove the mesh filter. [10]
6. Once the cup cover is removed, pull the HSpin-Core+ Technology assembly away from the main body. [11A] Hold the
top of the motor cover [K1] and remove the mesh filter by pulling away. [11B]
7. Press the two exhaust filter release buttons and then remove the exhaust filter. [12A, 12B]
8. When cleaning the the filters, wash the mesh filter [K2] and exhaust filter [T] in luke warm water. [13] Please ensure
all parts are completely dry before reassembling. [14]
9. When reassembling the HSpin-Core+ Technology, firstly reattach the mesh filter to the motor cover, [15A] then align
this assembly with the motor shaft, paying particular attention to the flat surface on the motor shaft. [15B]
10. Secondly again hold mesh filter and refit cover cup: rotate in an anti-clockwise direction to lock [16]. PLEASE
ENSURE YOU DO NOT OVERTIGHTEN AS THIS MAY DAMAGE THE THREAD.
11. Complete reassembly of the handheld unit and then attach it to the wall Mount.
NOTE: Do not use hot water or detergents when cleaning the exhaust filters. In the unlikely event of the exhaust filters
becoming damaged, fit a genuine Hoover replacement. Do not try use the product without a filter fitted.
IMPORTANT: For optimum performance, always keep your mesh filter clean. We recommend that the filter should be
washed at least once a month.
Changing and Cleaning the Agitator
IMPORTANT: Always switch off the cleaner before changing and cleaning the agitator.
1. Detach the agitator release button flap. It is positioned on the lateral part of the nozzle. [17a]
2. Hold the agitator release flap and remove the agitator. [17b]
3. To clean the Intense Floor Roller, remove excess debris using scissors. [17c]
4. To clean the Deep Care Roller, rinse with water [17d] and leave to dry for 24hrs. [17e]
5. Re-fit the agitator. [17f] The agitator can only fit in one direction.
6. Close the agitator release flap to secure the agitator in position. [17g]
Replacing the Batteries
This cleaner is fitted with a rechargeable Lithium ion battery pack and it is replaceable.
WARNING: Only use approved replacement parts for your cleaner. Using parts not validated by Hoover are dangerous
and will invalidate your guarantee.
WARNING: Do not try to open the battery pack and repair it by yourself.
1. Pull down the battery pack release button and the battery pack will be pushed out short distance automatic. [8A]
2. Drag the battery pack slowly from the slot. [8B]
3. Removed the old battery pack and replace with the new battery pack.
4. Dispose of the batteries safely. Used batteries should be taken to a recycling station and not disposed off with
household waste.
TROUBLESHOOTING
Should you have any problem with you cleaner, follow this simple check list before calling the Hoover Customer Service
Centre:
A. Cleaner does not switch on
Check if the cleaner is charged.
Check if the battery pack is assembled in place.
B. HSpin-Core+ Technology motor stop working
Check if the HSpin-Core+Technology motor is blocked.
Clear it and ensure the continuous mode lever is off. Once this is done simply press the on/off button, the
product will restart after a few seconds.
Check if dust bin or dust bin not assemble well.
C. Loss of suction or no suction
Empty the dust cup and wash the mesh filter and clean the
Remove nozzle and check for any blockages in the duct.
HSpin-Core+
Technology assembly.
6
GB