6.5.2
Initial opening is insufficient
•
Open the blades.
•
Place one spreading tip in the opening.
•
Close the blades until the material is clamped.
•
Bend the clamped material out of the way.
•
Repeat this procedure until there is sufficient space to place both spreading tips.
•
Force the parts apart.
6.5.3
No initial opening
•
Use a different tool or accessory to make an opening.
•
Continue with section 6.5.1 or 6.5.2, depending on the opening created.
6.6
After use
6.6.1
Shut down
•
Close the blades (with the tips) over each other to prevent injury. Do not fully close them so that the
tool can be stored without pressure.
•
Place the control ring (fig. 2, item 9) in neutral position.
•
Place the pump handle in the handle storage (fig. 2, item 3) by sliding the pump handle locking ring
towards the pump handle and tilting the pump handle in the direction of the blades.
6.6.2
Inspection
•
Check the unit for completeness, leaks and damage. Do not use the unit if it leaks or is damaged
and contact the Holmatro dealer.
•
Check the accessories used for completeness and damage. Replace them if the damage is
considerable.
•
Inspect the spreading tips. Replace the blades if the damage is considerable.
•
Check that the carrying handle is firmly attached.
HCT5111 (RH)(ST)/HCT5117 (RH)(ST)
916.001.234_004
EN
27