Installation instructions

A: Exhaust air connection
B: Electrical connection
C: Front bracket
D: Nut support
E: Mounting bracket
F: Fixing holes
G: Spring
1. (For extraction mode) Prepare a suit-
able exhaust air guide in the ceiling, or
wall.
2. Make cut out in the fitted wall unit.
Floor of the wall unit should be min 19
mm.
DHL 8: A = 791 mm
DHL 11: A = 1091 mm
3. Drill Ø4mm holes with the template
H4.2587D at the sides of the furniture.
(4 holes Ø4mm for each bracket).
Be careful with the wall thickness of the
unit!
Minimum distance between the lower
edge of the extractor hood and the
hobes is 500 mm.
4. Fix mounting brackets (2.) with 8
screws 20x6 mm
5. Assemble the nut support (3.) on the
mounting brackets.
5a. When using ducting out to the back
side, you can change the air flow direc-
tion of the hood. Disassemble the metal
plate at the back side first. Then install
the hood in the cabinet while blower with
support is inside the hood. The valve
should be installed to the flexible tubing
inside the wall.
en