6. Faults
The most frequent root causes and required countermeasures
are listed in the following table.
Fault
No or undefined
switching function
Magnetic float
switch cannot be
mounted at the
intended position in
the container.
CAUTION!
Bodily injuries, property and environmental damages
If faults cannot be rectified with the help of the listed measures,
immediately shut the unit off.
Ensure the pressure is switched off and secure the unit against
unintentionally being switched on.
Contact the manufacturer.
If return shipment is necessary, follow the instructions in Chapter
8.2 "Return Shipment".
Operating Instructions Horizontal Magnetic Float Switch - HLS
Cause
Incorrect PIN assignment
Temperature contact
defective
Reed contact
mechanically or
electrically defective
Process connection of the
magnetic float switch and
container are not
compatible
Measure
Comparison with
connection diagram
Return shipment to the
factory
Return shipment to the
factory
Modification of the
container
Modification of the
magnetic float switch
at the factory.
21