46
NOTE: During the safety stop, the maxi-
mum depth can be displayed pressing the
button.
DANGER: At the end of the safety
stop, many divers use to quickly reach
the surface, sometimes even inflating
the Buoyancy Control Device. It is a
very severe error which may lead to
decompression sickness. The last me-
ters before surface in fact are the most
critical and the percentage variations
of the pressure are significant. The last
section of the ascent to surface in fact
should be covered in no less than a mi-
nute.
DECOMPRESSION FOREWARNING
Every time the time available within the curve,
shown on the display by the NO DECO icon,
decreases to 3 minutes, Leonardo warns the
diver. The digit with the remaining minutes and
the NO DECO icon flash and a sound alarm is
issued. It means that the diver is approaching
the no decompression limits. A decompression
is required.
DEEP STOP .
(im. 21)
In order to avoid the risks related to the mi-
crobubbles forming during the ascent, Leo-
nardo is able to suggest a DEEP STOP of 1 - 2
minutes (in case of dive with decompression)
at variable depth depending on the dive pro-
file. During the dive, if the profile requires it,
DEEP STOP is displayed and an acoustic signal
is issued. The stop icon with the depth and the
time in minutes is displayed.
(im. 20)