Connecting Data and Power
A maximum of 32 luminaires may be connected in any one DMX data link.
Note: This maximum limit applies to the luminaire "daisy chain" only. Your system or console may
require fewer luminaires on a single data link path. Consult your console documentation for more
information.
To connect power and data:
Step 1. Connect data cable from console to first luminaire in chain at DATA IN connector.
Step 2. If required, connect additional data cables from DATA THRU connectors to DATA IN
connectors of remaining luminaires in link.
Step 3. At last luminaire in link, install male termination connector at DATA THRU connector.
(Luminaires and other devices on the same DMX chain may not function properly without
termination.)
AC In
Step 4. Connect AC Input Cable connector to power input source.
Step 5. Dress AC input and data cables and secure them so that they will not interfere with
luminaire head and yoke movement.
02.96 87.000 1 C
Data In
AC In
Data Thru
VL440 / VL770 / VL880 Luminaire Channel Requirements
Model
VL440 Spot
VL770 Spot
VL880 Spot
Figure 2-11: Data Link
31 Octo be r 20 13
I
: I
NSTALLATION
NSTALLATION
Termination
Data Thru
DMX512 Channels
30 Channels
30 Channels
30 Channels
P
ROCEDURES
AC In
2
25