GB
D
19. Correction of Malfunctions
Problem
No coating material
emerges from the
nozzle
Coating material
drips from the
nozzle
38
38
Cause
•
Nozzle clogged
•
Material volume setting
turned too far to the left
•
When trigger is not
completely pushed through,
the feed pump is not
switched on
•
The control hose not inserted
into the grab handle
•
Control hose blocked or
damaged
•
Container empty
•
Suction hose or suction ilter
is blocked
•
The suction hose is
disconnected from the basic
device
•
The suction hose is not in
the paint
•
Pull wire is disconnected or
not tight enough
•
The material hose is
disconnected from the spray
head or basic device
•
Pump is defect
•
Coating material assembly
at air cap, nozzle or needle
•
Nozzle loose
•
Nozzle seal worn
•
Nozzle worn
•
Pull wire is too tight
WallPerfect W 995
WallPerfect W 995
Remedy
➞ Clean
➞ Turn to the right
➞ Push trigger through
completely
➞ Insert the control hose
(ig.3,1)
➞ Clean or replace
➞ New paint container
➞ Clean
➞ Reattach the suction hose
➞ Immerse the suction hose
➞ Connect and tighten the
pull wire
➞ Reattach the material hose
➞ Please contact Wagner
Service
➞ Clean
➞ Union nut tighten
➞ Change
➞ Change
➞ Reduce tension