Operating keys of the ENS 3000
E
4.
Digital display
After switching on the supply voltage, "ENS" appears briefly in the display. The
display then indicates which parameter (fluid level or temperature) will be
displayed and starts to indicate the actual value (basic setting).
If the level exceeds or is lower than the measuring zone of the electronic level
sensor, the following sequence is displayed:
In the basic settings the display can be altered as follows:
Display of the peak fluid level measured "n.TOP"
Continuously displays the highest fluid level measured in the system since the
unit was last switched on or reset.
Display of the lowest fluid level "n.MIN"
Continuously displays the lowest fluid level measured in the system since the
unit was last switched on or reset.
Display of the actual temperature "TEMP"
Display of the peak temperature"T.TOP"
Continuously displays the highest temperature measured in the system since
the unit was last switched on or reset.
Display of the lowest temperature "T.MIN"
Continuously displays the lowest temperature measured in the system since
the unit was last switched on or reset.
34
indicates if
temperature in °C or °F
4-digit
digital display
Display indicating
fluid level unit (cm/inch)
LED-Display of
the active switching point
Keys for setting
switching points, switch-back points
and additional functions
2 s
2 s
2 s
2 s
niv = level
Flashing display