2.4 Installation
Connection for MMA welding
The connection shown in the figure produces
reverse polarity welding. To obtain straight polar-
ity welding, reserve the connection.
- Connect (1) the earth clamp to the negative socket (-) (2) of
the power source.
- Connect (3) the electrode holder to the positive socket (+) (4)
of the power source.
Connection for TIG welding
- Connect the power cable (5) to the negative pole (-) (6) of the
terminal strip to change polarity (see "Changing the welding
polarity").
- Connect (7) the earth clamp to the positive socket (+) (8) of
the power source.
- Connect the TIG torch coupling (9) to the torch socket (10) of
the power source.
- Connect the gas hose (11) from the cylinder to the rear gas
connection (12).
37