1. Remove the rear cover.
2. Put an extension on the valve.
3. Open the valve.
4. Remove the radiator coolant lid. The radiator coolant
drains from the system.
5. Close the valve.
6. Fill with radiator coolant until the level is at the start
of the tube in the coolant tank. Refer to
data on page 44 for correct radiator coolant type
and mixture.
1223 - 002 - 09.07.2019
To replace the air filters
1. Open the 3 clamps of the air filter housing (A) and
remove the air filter housing.
2. Replace the outer air filter (B) and the inner air filter
(C).
3. Install the air filters in opposite sequence.
Note: If the 3 clamps of the air filter housing cannot
be closed, the outer air filter is not correctly installed.

Battery maintenance

Note: The battery on your product is maintenance free.
Do not open or remove the caps or the covers.
To connect and disconnect the battery
1. Connect the red battery cable (A) to the POSITIVE
(+) battery terminal on the battery.
C
Technical
2. Install the battery holder (B).
3. Connect the black battery cable (C) to the
NEGATIVE (-) battery terminal on the battery.
4. Disconnect the battery cables in the opposite
sequence of how they were connected.
To do a check of the battery
Do a check of the battery daily.
B
A
-
B
WARNING: Always disconnect the
NEGATIVE (-) battery terminal first.
C
+