6. Setting of the presets
If a push-button with an arrow or the "P" push-button is
pressed, the device jumps from the display of the counter
to the display of the preset. About 4 seconds after the last
operation of the button, the device jumps back to the dis-
play of the counter and takes over a new preset value.
Exception: in the time counter mode, the new value is
taken over immediately.
Once the preset is displayed, the " " push-button allows to
choose the decade to be modified. This decade then blinks
at a 1 Hz frequency. The "" push-button allows you to
raise the value of the decade. On the most significant
decade, after the value "9", the sign "-" is displayed. The
following operation of the "" push-button displays "-1"
again. A new operation of the "" push-button lets the dis-
play of this decade start again at "0".
Caution: in case of automatic repetition, the preset cannot
be given negative values.
7. Connections
Only with the optional
serial interface
7.1 Terminal assignment X1
Supply voltage and outputs
Terminal
AC versions
No
1
n.c.
2
n.c.
3
Output
Common relay contact (C)
Emitter when optocoupler output
4
Output Relay
Closing contact (NO)
5
Output Relay with opening contact (NC)
Collector when optocoupler output
6
Supply voltage
90...250 V AC
7
Supply voltage
90...250 V AC
Attention: In case of a
ting (reversed relay control), the connections of terminals 4
and 5 are reversed:
Terminal
AC and DC versions
No
4
Opening contact relay (NC)
5
Closing contact relay (NO)
10..30 VDC
versions
Operating voltage
10..30 V DC
0 VDC (GND)
and a
set-
7.2 Terminal assignment X2
Inputs
Terminal Designation
No
1
+24 VDC
2
0 VDC
(GND)
3
INP A
4
INP B
5
RESET
6
GATE
7
KEY
8. Technical characteristics
Supply voltage:
Display:
Polarity of the input signals:
Input resistance:
Counting frequency:
Minimum pulse duration for control inputs:
Input switching level:
Pulse shape:
Accuracy in the frequency meter/speed indicator mode:
Accuracy in the time counter/operating
time counter mode:
Output :
AC versions
10..30 VDC
Sensor supply
Not
voltage
connected
Reference volt-
Not
age
connected
Counting input A
Counting input B
Reset input
GATE input
Push-button locking input
90 ... 260 V AC, 9VA max.
ext. fuse protection: T 0.1 A or
10 ... 30 V DC, 1W max.
ext. fuse protection: T 0.125 A
6 digits, red 7-segment
LED's, display height 8 mm
programmable in common for
all inputs (npn or pnp).
approximately. 10 k
20 kHz (10 kHz with phase dis-
criminator), can be reduced to
30 Hz. In case of automatic
repetition, 1.2 kHz without loss
of pulses (700 Hz with phase
discriminator and pulse multi-
plication by 2).
5 ms
With AC supply voltage:
log."0": 0..4 VDC
log."1":12..30 VDC
With DC supply voltage:
log."0": 0..0,2 x U
B
log."1": 0,6 x U
..30 V DC
B
any shape
(Schmitt trigger inputs)
< 0,1 %
± 50 ppm
Relay with potential-free
change-over contact, program-
mable as opening or closing
contact.
7