Herunterladen Inhalt Inhalt Diese Seite drucken

Terminal Assignment; Technical Data; Delivery Includes; Ordering Code - Kübler CODIX 525 Bedienungsanleitung

Elektronischer summier- und frequenzzähler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.9 Max. time to wait until „0" is displayed
This parameter indicates, how long it takes at
active measuring, until „0" is displayed
4.10 End of programming
6
max. time to wait 01.1 s
(min. value)
max. time to wait 99.9 s
Programming routine will
be passed through once
again. All parameters can
be checked.
Programming routine will
be left and the new
parameters will be stored.
Afterwards the device is
ready to use.

5. Terminal assignment

1
10-30 VDC
2
0 V (GND)
3
INP
4
---
5
RESET

6. Technical data

Supply voltage:
10...30 VDC, max. 50 mA
Display:
6digit LED-Display, 8 mm character height
Polarity of input signals:
programmable for inputs in common (npn or pnp)
Input resitance: appr. 10 k
Count frequency:
20 kHz can be damped to 30 Hz
Min. pulse length of the reset input: 5 ms
Input sensitivity:
log. „0": 0 VDC..0,2xU
log. „1": 0,6 x U
Pulse shape: variable (Schmitt Trigger
characteristic)
Data retention:
6
via EEPROM 1x10
memory cycles or 10 years
Accuracy:
frequency meter/speed indicator mode: < 0,1 %
Noise immunity:
EN 50081-2; EN 55011 class B; EN 50082-2
Ambient temperature: -10 °C...+50 °C
Storage temperature: -25 °C...+70 °C
Weight: appr. 50 g
Protection: IP 65 (front)
Cleaning:
The front of the unit is only to be cleaned with a
soft wet (water !) cloth.

7. Delivery includes:

- CODIX 525
- Panel mounting clip
- Bezel for screw mount, panel cut-out 50x25 mm
- Bezel for clip mount, panel cut-out 50x25 mm
- Sealing

8. Ordering code:

6.525.012.300
W
B
..30 VDC
B

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis