RADIAL application MSK5000R with MR500:
Signal
A before B
Fig.7: Definition of the counting direction with ma-
gnetic ring and assemblage sensor/magnetic ring,
gap measure, tolerances
4. Electrical connection
•
Wiring must only be carried out with power off!
•
Check all lines and connections before switching
on the equipment!
Interference and distortion
All connections are protected against the effects
of interference. The location should be selected
to ensure that no capacitive or inductive in-
terferences can affect the sensor or the con-
nection lines! Suitable wiring layout and choice
of cable can minimise the effects of interference
(eg. interference caused by SMPS, motors, cyclic
controls and contactors).
Necessary measures
•
Only screened cable should be used. Wire cross sec-
tion is to be at least 0,14mm², max. 0,5mm².
•
Wiring to the screen and ground (0V) must
be secured to a good point. Ensure that the
connection of the screen and earth is made to
a large surface area with a sound connection to
minimise impedance.
•
The system should be positioned well away from
cables with interference; if necessary a protective
screen or metal housing must be provided. The
running of wiring parallel to the mains supply
should be avoided.
•
Contactor coils must be linked with spark sup-
MSK5000R
+MB500+MR500
Laser
marking
Undercut
the solid shaft
for tread plug
is recommen-
ded
Direction of rotation
of magnetic ring
Datum 24.06.2009
pression.
Supply voltage
The voltages depend on the sensor designs; they
are to be taken from the delivery documentation
at
and the identification plate.
eg.:
4.1 Pin assignment
Connection with M12 plug.
not
Signal
inverted
I
Pin 5
/I
- - -
B
4
/B
- - -
/A
- - -
A
2
GND
3
+UB
1
5. Commissioning
Following proper installation and wiring, the
measuring system can be commissioned by
switching on the supply voltage.
The measuring system MSK5000/MB500TMR500 is
a component of an incremental measuring system
which must be referenced at a defined position
(reference point) for absolute measurement. For
this purpose, the reference signal must be linked
to the signal of a reference value encoder (e.g.,
proximity switch).
6. Travel speeds (m/s)
Resolution in µm
10
20
20
10
6,5
3
1,5
0,75
0,395
0,26
Art.Nr. 84973
5VDC
5 pole
inverted
Pin 1
2
8 pole
3
4
5
6
viewing side =
7
plug-in side
8
plug pin
5
20
0,12
2083,4
10
0,29
862,1
5
0,48
520,84
3,25
1
250
1,54
2
125
0,75
4
62,5
0,375
8
31,25
0,195
16
15,625
0,13
24
10,42
Änd. Stand 194/09