9. Specifications

9.4 Pressure gauges with output signal

Model PGT23.063
Pressure limitation
Steady
Fluctuating
EN
Short time
Temperature effect
Wetted materials
Process connection, pressure
element
Non-wetted materials
Case, bayonet ring
Movement
Dial
Pointer
Window
Ingress protection per IEC/EN 60529 IP54; option: IP65
For further specifications see data sheet PV 12.03
Models PGT23.100, PGT23.160, PGT26.100, PGT26.160
Pressure limitation
Steady
Fluctuating
Short time
Temperature effect
Wetted materials
Process connection, pressure
element
Non-wetted materials
Case, bayonet ring
Movement
Dial
Instrument pointer
Pointer
Window
Ingress protection per IEC/EN 60529 IP65
1) Ingress protection IP54 with lower back mount.
For further specifications see data sheet PV 12.04
28
3/4 x full scale value
2/3 x full scale value
Full scale value
When the temperature of the measuring system deviates from
the reference temperature (+20 °C): max. ±0.8 %/10 K of full
scale value
Stainless steel 316L
Stainless steel
Brass
Aluminium, white, black lettering
Aluminium, black
Polycarbonate or laminated safety glass
Full scale value
0.9 x full scale value
1.3 x full scale value
When the temperature of the measuring system deviates from
the reference temperature (+20 °C): max. ±0.4 %/10 K of full
scale value
PGT23.100, PGT23.160: Stainless steel 316L
PGT26.100, PGT26.160: Monel
Stainless steel
Brass
Aluminium, white, black lettering
Aluminium, black
Aluminium, red
Laminated safety glass
; option: IP66
1)
Pressure gauges with output signal, optionally for hazardous areas