Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens SITRANS LR560 Kurzanleitung Seite 20

Radar transmitters (ma/hart)
Vorschau ausblenden Andere Handbücher für SITRANS LR560:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 63
2) Non-incendive and Dust Ignition Proof wiring (US/Canada)
FM/CSA Class 1, Div 2 connection drawing number A5E02795836 can be downloaded from
the product page of our website at: www.siemens.com/sitransLR560. Go to Support >
Installation Drawings > Level Measurement > Continuous - Radar.
• For power demands, see
Instructions specific to hazardous area installations
(Reference European ATEX Directive 94/9/EC, Annex II, 1.0.6)
Installation shall be performed only by qualified personnel and in accordance with
Note:
local governing regulations.
The following instructions apply to equipment covered by certificate numbers Sira
09ATEX9356X and Sira 09ATEX4357X:
1)
For use and assembly and details of marking/coding, refer to the main instructions.
2)
The equipment is certified for use as Category 1D, 1/2D and 2D equipment per certificate
Sira 09ATEX9356X and may be used in hazardous zones 20, 21 and 22. The equipment is
also certified for use as Category 3G equipment per certificate Sira 09ATEX4357X and
may be used in hazardous zone 2.
3)
This equipment has a maximum surface temperature of 139 °C (in an 80°C ambient). Refer
to the applicable code of practice for selection of this equipment with respect to specific
dust ignition temperatures.
4)
The equipment is certified for use in an ambient temperature range of -40 °C to 80 °C.
5)
The equipment has not been assessed as a safety related device (as referred to by
Directive 94/9/EC Annex II, clause 1.5).
6)
Installation and inspection of this equipment shall be carried out by suitably trained and
authorized personnel in accordance with the applicable code of practice.
7)
The equipment shall be installed such that the supply cable is protected from mechanical
damage. The cable shall not be subjected to tension or torque. The equipment
manufacturer is not responsible for providing the supply cable.
8)
Repair of this equipment shall be carried out by suitably trained and authorized personnel
in accordance with the applicable code of practice.
Page EN-18
SITRANS LR560 (HART) – QUICK START MANUAL
Temperature De-Rating Curve
SPECIAL CONDITIONS FOR SAFE USE
See
on page 16.
7ML19985XF81
on page 19
.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis