80
Fumes motor fault
Fumes probe failure.
High ue gas temperature
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The ue exhaust pipe is blocked.
The pellet feed-box is empty.
Pellet feed calibration inadequate.
No current during the ignition phase.
The pellet feed-box is empty.
No pellet feed.
The motor reducer does not feed pellets.
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The ue exhaust pipe is blocked
Flow sensor faulty.
Sensor disconnected
Pressure sensor faulty
The water in the generator has exceeded 95°C.
Possible air in the system.
Lack of adequate circulation.
Lack of or inadequate safety zone.
Possible circulator anomaly.
The automatic door of the brazier
is blocked.
The system pressure read by the pressure
switch is too low.
Presence of air in the system:
Possible lack of water or leaks due to
anomalies in some system component.
H2O probe failure
The pressure of the water has exceeded
the max threshold
Anomalous functioning
of pellet feeding
Anomalous functioning
pellet engine
Faulty boiler probe
Faulty boiler probe
Contact after-sales centre
Contact after-sales centre
Check pellet feed (see "Pellet feed adjustment"). If the problem
cannot be solved, contact an authorised technician.
Check for the presence of pellets in the pellet tank
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe, of the sensor in the
primary air channel and the combustion chamber.
Contact after-sales centre
Check for the presence of pellets in the feed-box.
Adjust the pellet ow (see "Pellet feed adjustment").
Check the procedures described in the "Ignition" chapter.
Set the generator to OFF though the button 1 and repeat the
procedures described in Chapter "Ignition".
Adjust the pellet ow (see "Pellet feed adjustment").
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion
chamber.
Contact after-sales centre
Contact after-sales centre
Contact the after-sales centre
Contact the after-sales centre
Contact the after-sales centre
Check that the expansion vessels are not damaged or
under-dimensioned
Check that the cold system is loaded at the correct pressure
Contact the technical support
Contact the technical support
Contact the after-sales centre
Contact the after-sales centre