Safety regulations
HAZARD: EXPLOSION HAZARD DUE TO
INCOMPATIBLE MATERIALS
Will cause severe injury or property damage.
PREVENTION:
• Do not use materials containing bleach or chlorine.
• Do not use halogenated hydrocarbon solvents such
as methylene chloride and 1,1,1 - trichloroethane.
They are not compatible with aluminum and may
cause an explosion. If you are unsure of a material's
compatibility with aluminum, contact your coating's
supplier.
HAZARD: GENERAL
This product can cause severe injury or property
damage.
PREVENTION:
• Read all instructions and safety precautions before
operating equipment.
• Follow all appropriate local, state, and national codes
governing ventilation, fire prevention, and operation.
• Pulling the trigger causes a recoil force to the hand
that is holding the spray gun. The recoil force of the
spray gun is particularly powerful when the tip has
been removed and a high pressure has been set on
the airless pump. When cleaning without a spray tip,
set the pressure control knob to the lowest pressure.
• Use only manufacturer authorized parts. User
assumes all risks and liabilities when using parts that
do not meet the minimum specifications and safety
devices of the pump manufacturer.
• Before each use, check all hoses for cuts, leaks,
abrasion or bulging of cover. Check for damage or
movement of couplings. Immediately replace the hose
if any of these conditions exist. Never repair a paint
hose. Replace it with another earthed high-pressure
hose.
• Make sure power cord, air hose and spray hoses are
routed in such a manner to minimize slip, trip and fall
hazard.
• Clean up all material and solvent spills immediately to
prevent slip hazard.
• ALWAYS follow the material manufacturer's
instructions for safe handling of paint and solvents.
• Do not use this unit in workshops that are covered
under the explosion prevention regulations.
• Always unplug cord from outlet before working on
equipment (electric units only).
• Always keep the power cord plug in sight during usage
to prevent any accidental shutdown or startup.
• Wear ear protection. This unit can produce noise
levels above 85 dB(A).
• Device weighs in excess of 36 kg. Three-person lift is
required.
• Never leave this equipment unattended. Keep away
from children or anyone not familiar with the operation
of airless equipment.
• Do not move unit while unit is running.
• Do not spray on windy days.
Performance Series 850e
GB
HAZARD: HAZARDOUS VAPORS
Paints, solvents, insecticides, and other materials
can be harmful if inhaled or come in contact with
body. Vapors can cause severe nausea, fainting, or
poisoning.
PREVENTION:
• Use a respirator or mask if vapors can be inhaled.
Read all instructions supplied with the mask to be sure
it will provide the necessary protection.
• Wear protective eyewear.
• Wear protective clothing as required by coating
manufacturer.
1.1
Earthing Instructions
Electric models must be earthed. In the event of an
electrical short circuit, earthing reduces the risk of electric
PE
shock by providing an escape wire for the electric current.
This product is equipped with a cord having an earthing
wire with an appropriate earthing plug. The plug must be
plugged into an outlet that is properly installed and earthed
in accordance with all local codes and ordinances.
DANGER — Improper installation of the earthing plug
can result in a risk of electric shock. If repair or
replacement of the cord or plug is necessary, do not
connect the green earthing wire to either blade
terminal. The wire with insulation having a green outer
surface with or without yellow stripes is the earthing
wire and must be connected to the earthing pin.
Check with a qualified electrician or serviceman if the earthing
instructions are not completely understood, or if you are in doubt as to
whether the product is properly earthed. Do not modify the plug provided.
If the plug will not fit the outlet, have the proper outlet installed by a
qualified electrician.
Caution – The power cord for this equipment acts as an
emergency stop/emergency switching off device. The
power cord must be placed near an easily accessible,
unobstructed socket-outlet.
Work or repairs at the electrical equipment:
These may only be carried out by a skilled electrician. No liability is
assumed for incorrect installation.
A list of the materials used in the construction of the equipment will be
made available on request to validate compatibility with the coating
materials to be used.
Operating Temperature
This equipment will operate correctly in its intended ambient, at a
minimum between +10°C and +40°C.
Relative Humidity
The equipment will operate correctly within an environment at 50% RH,
+40°C. Higher RH may be allowed at lower temperatures.
Measures shall be taken by the Purchaser to avoid the harmful effects of
occasional condensation.
Altitude
This equipment will operate correctly up to 2100 m above mean sea level.
Transportation and Storage
This equipment will withstand, or has been protected against,
transportation and storage temperatures of -25°C to +55°C and for short
periods up to +70°C.
It has been packaged to prevent damage from the effects of normal
humidity, vibration and shock.
23