7 Maintenance and cleaning
EN - 10
NOTE
• The maintenance intervals given are standard values and refer to single-
shift operation.
• Maintenance and cleaning work may only be carried out by qualified
and trained specialists.
• Check coolant hoses, seals, and connections for damage and tightness.
Replace as necessary.
• Always wear your personal protective equipment when performing
maintenance and cleaning work.
Sharpening the tungsten electrode
DANGER
Health hazards caused by radioactive substances
Radioactive substances are released during welding and sharpening of
tungsten electrodes.
• Use a suitable extractor unit.
Sharpening the tungsten electrode depends on wear and must therefore be
carried out when required. To sharpen the tungsten electrode, use a
sharpening device with a diamond disc.
Abb. 4
Sharpening the tungsten electrode
• The point is sharpened longitudinally through the centre axis.
• Automatic regulation of the tungsten electrode drive by gravity.
• Can be set for all electrode diameters.
• Continuous adjustment of the angle.
®
ABITIG