Herunterladen Inhalt Inhalt Diese Seite drucken

bürkert 1062 Bedienungsanleitung Seite 18

Elektrischer auf/zu-stellungsrückmelder
Vorschau ausblenden Andere Handbücher für 1062:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

E
F
G
18
Check that the seals have been fitted
and that they are undamaged. Replace
them if necessary.
Put thread lock into the internal thread
in the duplication rod "E".
Unscrew the small transparent cap "F"
on the actuator, preferably by hand or
using a suitable tool in order not to
damage it (except for actuators size
40mm).
Pump air into the actuator on a valve
which is normally closed (function "A")
or has a double effect (function "I") so
that the actuator rod moves to the top
position.
Unscrew the visual position feedback
"G" using a hexagonal male spanner.
english
Type 1062
Assembly
Check that the seal "H" is fitted and
E
that it is correctly positioned inside
the actuator.
Insert the duplication system "D" into
D
the actuator.
H
Screw the duplication rod "E" onto
the actuator rod "J".
J
Tighten the adaptor until free contact
is obtained with the top of the
actuator, using a flat No 27 spanner.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis