Operating instructions
Before starting to use the device, it is essential that the
Operating Instructions and „Important instructions" be
read carefully. The vehicle owner is responsible for ensuring
that the device can be operated in the proper manner.
Infrared (IR) remote handset
+/– = Setting
Operating level,
Timer, Temperature,
Fan speed
a
= MODE
Operating mode
selector switch
FAN MODE
Ventilation only
COOL MODE
Cooling and ventilation
b
= No function
c
= TEMP.
Desired interior
temperature
16 to 31°C
d
= No function
e
= TIMER off
Set timer to 1 to 15 hours
f
= RESEND
Send the settings of the remote control to device
again
g
= ON/OFF
On/Off switch
Taking into operation
Before switching on, be sure to check that the campsite power
supply fusing is sufficient for 700 W (230 V – at least 3 A).
In order to prevent the power cable for the caravan from
overheating (minimum cross-section 3 x 2.5 mm²) the
cable drum must be fully unwound.
The remote handset must always be pointed at the infra-
red (IR) receiver in order to execute the individual switching
commands.
1. Switch the Saphir compact on using button „g" on the re-
mote handset. The „COOL MODE" that was previously selected
using the remote handset is automatically used.
2. Set the desired operating mode using the button „a".
FAN MODE:
Ventilation only without cooling.
Select the required fan speed FAN LOW or FAN HIGH
using the „+" and „–" buttons.
COOL MODE: Cooling with 3 levels.
The room temperature can be individually ad-
justed. The green indicator lamp on the receiver
indicates that the compressor is running. Select
the required cooling setting COOL LOW, COOL or
COOL HIGH using the „+" and „–" buttons.
The COOL LOW setting acts as a sleep function. The internal
and external fans operate at a slower speed in this mode
in order to minimise the amount of noise that is generated.
3. Select the required room temperature using the „c", „+"
and „–" buttons.
12
COOL
MODE
COOL LOW
TIMER
FAN LOW
Hr.
COOL
FAN HIGH
COOL HIGH
TEMP.
°C
a
b
MODE
c
e
d
f
TEMP.
TIMER RESEND
g
ON / OFF
Saphir compact
When the room temperature that was selected using the
remote handset is reached in cooling mode, the compressor
switches off and the green indicator lamp in the receiver goes
off. The circulation fan continues to run in order to provide
ventilation. If the room temperature setting is exceeded the
device automatically reverts to cooling mode.
Switching off
To switch off, press the button „g" on the remote control once
again.
If the air conditioning unit is switched on again within
approximately 3 minutes, the green indicator lamp
flashes. The recirculated air fan runs, and the compressor is
activated after a maximum of 3 minutes.
Timer off
The air conditioning unit deactivation time can be set up to
15 hours in advance using the integrated timer, starting from
the current time.
To carry out programming, first switch the device to remote
control mode with the switch „g".
Then set the operating mode and the room temperature using
buttons „a", „c", „+", and „-".
Then select the required deactivation time (1 – 15 hours) using
the „e" button (TIMER).
The programming is not active unless the air condi-
tioning unit is switched on. The remote handset can
be deactivated by covering the infrared transmitter on the
front of the remote handset. This prevents unintentional air
conditioning unit deactivation and accidental deactivation time
reprogramming.
IR receiver and manual on/off
There is an additional pushbutton on the receiver (m), with
which the unit can also be switched on and off without the
remote control (e.g. with a ballpoint pen).
Saphir compact
LED 2
m
LED 1
Operating indicator
LED 1 green illuminated
LED 1 green short flash
LED 1 green flashes briefly – Only during operation with
LED 2 red short flash
LED 2 red illuminated
Red LED illuminates
The unit is indicating a fault. Switch unit off, wait for a short
time and switch on again. If the red LED continues to illumi-
nate, please contact Truma Service.
If the unit is switched on using
this pushbutton, the system is
automatically reset to the factory
settings (COOL HIGH, TEMP. 21°C).
– Cooling (COOL LOW, COOL or
COOL HIGH)
– The recirculated air fan runs,
and the compressor is also
activated after a maximum of
3 minutes
power inverter: Waits until
engine starts or function is
changed using remote handset
– Data transfer in progress or
supply voltage being connected
– Fault