T e c h n i c a l D a t a /
t r o u b l e s h o o t i n g M L 4 0

Flow diagram:

From • the function is guaranteed
The ideal spray pattern will be reached from
2 bar pressure.
Trouble shooting
Failure
No function
Light fails
After a certain time of
showering the temperature
changes
Outlet temperature does
not correspond with the
adjusted temperature
Thermostat alignment
impossible
Thermostat alignment is
difficult
58
Possible cause
Floor shut-off device is
closed
Shut-off valve of the
thermostat is closed
Filter is polluted
Halogen bulb defect
Connection to the lighting
is interrupted
Transformer defect
Pressure switch defect
Not enough stored hot water
Hot water feeding
temperature too low
No thermostat alignment
was performed
Hot - and cold water supply
hoses are wrong way around
Cartridge defect
Temperature and pressure
fluctuations
( M L = m a n u a l V e r s i o n )
Power supply:
Rated output:
Transformer:
Protection type:
Minimum water pressure:
Applied pressure:
Recommended pressure:
Test pressure:
Hot water temperature:
Recommended hot water
temperature:
Temperature scale:
Safety block:
Flow rate at 3 bar pressure
Over head shower:
Hand shower:
Body showers:
Hand showers + body showers:
Over head showers+ body showers
Over head showers + hand showers
Remedy
Open floor shut-off device
Open shut-off valve
Clean filter
Replace halogen bulb
Plug in the connector of the lights
Replace transformer
Contact technical service
Increase stored hot water or the temperature
Increase stored hot water cylinder temperature
Perform thermostat alignment
Connect the supply hoses in the right
way and perform thermostat alignment
Replace cartridge by an authorised plumber
Balance cold- and hot water pressure
Increase temperature of the hot water cylinder
230V~ 50/60Hz
35 VA
Protection Class II
IP 65
1,5 bar
max.10 bar
2 – 5 bar
10 bar
max. 70° C
60° C
20° – 60° C
38° C
19 l/min
12 l/min
15 l/min
19 l/min
22 l/min
21 l/min