Faults
parts pouch [3],
Fault
No pressure builds up in
the device
pump
The nozzle does not
spray even though pres-
sure is present
Only spray, no atomi-
zation
The shut-off valve does
not close.
Liquid emerges without
the lever being activa-
ted..
AUS
USA
Cause
The pump is not screwed on
tightly
O-ring [12] on the pump is
faulty
Diaphragm [13] is defective
The valve disc [17] is dirty or
faulty
Filter [16]
and nozzle [14]
clogged
Insert [15] missing
Seal of the tension bolt [20]
not greased
Tension bolt [20] or
seal defective
16
NZ
Remedy
Screw the pump on tightly
Replace the O-ring
Replace the diaphragm
Clean or replace the valve disc
or /
is
Position the insert in the nozzle
Unscrew screw [18] from the
shut-off valve [6] to remove the
lever [19].
Unscrew screw seat [21] and
press out tension bolt [20].
Clean and grease seal of the
tension bolt [20] or renew tensi-
on bolt [20].
Install in reverse sequence.