SteamForce Pro
Model
SteamForce Pro 230V 7.5L
*Approx. steam time before the safety cut-out operates.
14. Descaling
Regular descaling is key to your steamer functioning properly.
i
Depending on water hardness, descale the steam wallpaper stripper
after 10 – 15 fills. Units which are defective due to a lack of descaling
are excluded from the guarantee!
•
Use a standard proprietary descaling agent. Observe the manufacturer's instructions
for use!
•
Mix the descaling agent with water (ratio 1:1).
•
Fill the steam wallpaper stripper with around 3.5 litres of descaling solution.
•
Switch the steam wallpaper stripper on for 10 minutes.
•
Switch the steam wallpaper stripper off again and unplug.
•
Leave the descaling solution to work for 30 minutes.
•
Then fully empty the steam wallpaper stripper.
•
Thoroughly rinse the unit two to three times with clear water to remove all descaling
solution residue.
15. Important Note regarding Product Liability!
In accordance with an EC directive, the manufacturer is liable for this product only if all parts
originate from or were approved by the manufacturer and the tools are assembled and
operated correctly. The use of other accessories and spare parts can partially or completely
invalidate the liability.
Boiler Capacity
Steam Time
80 -100 Minutes*
EN