BML SL1-ALZ _-_ _ ZZ- _ _ _ _ - _ _ _ _
Absolute Magnetically Coded Position Measuring System
4
Installation and connection (continued)
4.3.4
Working ranges, angles, distances, tolerances
and measuring accuracy – Curved application
Rotating application is only possible using
sensors in the BML SL1-ALZ1-... series.
Fig. 4-7:
Tolerances for applications with curved tape
Z
(air gap sensor/magnetic tape)
Z
(air gap between sensor/magnetic
tape with cover strip)
Y (lateral offset)
X (tangential offset)
Pitch
Yaw
Roll
Tab. 4-3:
Function ranges, angles, distances, and tolerances
12
english
Z
X
2000 mm
≤ 1.0 mm
0.85 mm
–Pitch
+Pitch
Z
Diameter
1000 mm
≤ 0.6 mm
0.45 mm
±0.5 mm
32.5 mm ±1 mm
±0.5°
±1°
±0.5°
Tangential point
400 mm
≤ 0.1 mm
–