3 Product description

Application area

Functional principle -
level measurement
Functional principle - in-
terface measurement
8
Information:
In this operating instructions manual, the optional instrument features
are described. The respective scope of delivery results from the order
3.2

Principle of operation

The BMD 1H is a level sensor with polished rod probe for continuous
level or interface measurement, particularly suitable for applications in
the food processing and pharmaceutical industry.
Optionally an autoclaved version with separable housing is available.
High frequency microwave pulses are guided along a steel cable or
a rod. Upon reaching the product surface, the microwave pulses are
ted as level.
h
Fig. 2: Level measurement
d Distance to the level
h
Height - Level
High frequency microwave impulses are guided along a steel cable or
rod. Upon reaching the product surface, a part of the microwave im-
layers are processed by the instrument.
-