Translation of the original instructions
TROUBLESHOOTING
Symptoms
The ON/OFF button does not
switch on when set to ON
(Start 300 only).
The machine's anmeter does
not fluctuate .
The charger is properly
connected but it does not
charge the battery
The anmeter's pin goes above
the maximum marking while
the device is set to minimum
intensity.
The fuse blows every time it is
replaced
The fuse trips.
After charging for a whole day,
the end of charge indicator
does not switch on.
START 200-300
Causes
No mains voltage
Power supply problem.
Clamps in short circuit or polarity
reversal.
The battery that you are trying to
charge is faulty.
Voltage error (12 -24V)
Following intensive use, your
device has entered thermal
protection mode.
Blown fuse
Bad clamp connections.
Wrong charge settings
Following intensive use, your
device has entered thermal
protection mode.
The battery is deeply discharged.
Voltage error (12 -24V)
Your battery has elements in short
circuit.
Polarity reversal
Wrong charge settings
Current overconsumption on the
battery
The machine is charging a 12V
battery in 24V mode
Starts are attempted while the
device is in charge mode.
You are charging a 12V battery in
24V mode
The battery is damaged
The machine is charging a 24V
battery in 12V mode
Remedies
Check that the power cord is plugged to a
230V 50/60Hz socket. Check the power supply
network.
Check your mains power supply.
Check that the device is on charge mode.
Check that the fuses have not melted and that
the circuit breaker is not tripped
Check the terminals' voltage with a voltmeter.
If this voltage jumps instantaneously to 2.5V
per element, the battery may be sulfated or
damaged.
Chck that the switch is on the right setting (12
or 24V)
Wait 1/4h so the device can cool down.
Replace the fuse by a new one.
Clean the terminals and the clamps. Check the
state of the cables and clamps.
Check that the selected voltage matches the
battery voltage.
Wait 1/4h so the device can cool down.
Keep charging using the minimum setting .
Chck that the switch is on the right setting (12
or 24V)
Damaged battery Replace the battery.
Connect the + clamp to the battery's (+) and
the + clamp to the battery's (-).
Check that the selected voltage matches the
battery voltage.
Do not draw any of the battery's current during
the charge
Set the switch to 12V.
Make sure to set the switch to « start » to
prevent damage to the machine. Reset the
circuit breaker.
Set the switch to 12V.
Change the battery.
Set the switch to 24V.
EN