3. Operation
3.5.2 Vane·Vent. (Lossnay)
<Accessing the menu>
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Main display:
Cursor
Page
F1
F2
F3
F4
<Vane setting>
Fri
Swing
Off
Vane
Vent.
Louver
F1
F2
F3
F4
<Vent. setting>
Fri
Low
Vent.
F1
F2
F3
F4
<Returning to the Main menu>
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Main display:
Cursor
Page
F1
F2
F3
F4
Notes:
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in "STAND BY" or "DEFROST" states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem-
perature setting.
Select "Vane·Louver·Vent.
(Lossnay)" from the Main menu
(refer to page 8), and press the
[SELECT] button.
Press the [F1] or [F2] button to go
through the vane setting options:
"Step 1", "Step 2", "Step 3", "Step
4", "Step 5", "Swing" and "Auto".
Select the desired setting.
Step 1
Step 2
Step 3
Swing
Step 4
Step 5
Swing
Auto
Auto
Select "Swing" to move the vanes
up and down automatically.
When set to "Step 1" through "Step
5", the vane will be fixed at the
selected angle.
Press the [F3] button to go through
the ventilation setting options in the
order of "Off", "Low", and "High".
* Settable only when LOSSNAY
unit is connected.
Off
Low
High
Off
Low
• The fan on some models of indoor
units may be interlocked with
certain models of ventilation units.
Press the [RETURN] button to go
back to the Main menu.
< How to set the fixed up/down air direction >
For PLA-EA series, only the particular outlet can be fixed to certain direc-
tion with the procedures below. Once fixed, only the set outlet is fixed
every time air conditioner is turned on. (Other outlets follow UP/DOWN air
direction setting of remote controller.)
Note:
This function cannot be set depending on the outdoor unit to be
connected.
Explanation of word
• "Refrigerant address No." and "Unit No." are the numbers given to
each air conditioner.
• "Outlet No." is the number given to each outlet of air conditioner.
(Refer to the illustration below.)
• "Up/Down air direction" is the direction (angle) to fix.
Remote controller setting
The airflow direction of this outlet
is controlled by the airflow direc-
tion setting of remote controller.
Outlet No. 2
Outlet No. 1
Note:
The outlet No. is indicated by the number of grooves on both
ends of each air outlet. Set the air direction while checking the
High
information shown on the remote controller display.
Air outlet identification marks
Horizontal airflow
Fixed
The airflow direction of this outlet is fixed
in particular direction.
* When it is cold because of direct
airflow, the airflow direction can be
fixed horizontally to avoid direct airflow.
Outlet No. 3
Outlet No. 4
9