3. Operation
3.6.4 Seasonal airfl ow function
Seasonal airflow
Seasonal airflow
Cooling/Heating
Select:
F1
F2
F3
F4

4. Timer

Timer functions are different by each remote controller.
For details on how to operate the remote controller, refer to the appropriate operation manual included with each remote controller.
B
A
Fig. 1
Fig. 2
Fig. 3
Fig. 4
C
Fig. 5
1 Select the setting with the [F4]
button.
OFF → Cooling only → Heating
only → Cooling/Heating → OFF...
After changing the setting, press
the [SELECT] button to save the
setting.
OFF: The function is disabled.
Cooling only: When the thermostat
turns off during cooling mode, the
vanes move up and down.
Heating only: When the thermostat
turns off during heating mode,
the vanes move to the horizontal
airfl ow direction to circulate the air.
Cooling/Heating: The function is
enabled during both cooling mode
and heating mode.
* In order to enable this function,
the airfl ow direction must be set to
"Auto".
Weekly schedule (Wireless remote controller)
■ The weekly schedule can be set to four operation patterns for each day of the week. The settings include the
on and off times and the set temperature.
<Editing mode>
1. Switching to the editing mode
1 Press the
button when the unit is operating or stopped.
blinks. (Fig. 1)
2. Selecting the setting pattern
1 Press the
button to select the setting pattern number.
Each time the
button is pressed, the pattern number A changes in the following order: 1 → 2 → 3 → 4.
3. Selecting the day of the week
1 Press the
button to select the day of the week to set.
Each time the
button is pressed, the day of the week B changes in the following order: Mon → Tue
→ Wed → Thu → Fri → Sat → Sun → All days.
4. Selecting the operation settings
1 Push the
button to select the operation on or off setting. (Fig. 2)
(
) is lighted.
Each time the
button is pressed, the setting changes in the following order:
2 Press the
button to select the operation time. (Fig. 3)
The operation time blinks.
Set the operation time using the
• The operation time can be set in 10-minute increments.
3 Push the
button to select the set temperature. (Fig. 4)
The set temperature blinks.
Set the temperature using the
• When setting the off operation, the temperature cannot be set.
When the AUTO (dual set point) mode is enabled, press the
C and the lower limit D. (Fig. 5)
4 By pressing the
5 Repeat steps 2–4 to select the settings for each day of the week.
<Transmitting the settings>
D
Point the transmission area of the wireless remote controller towards the receiver on the indoor unit and oper-
ate the controller. Confi rm that the indoor unit beeps 7 times.
Press the
button.
<Enabling the weekly schedule>
Press the
button.
The weekly schedule operates when
• The weekly schedule does not function when the On/Off timer is enabled.
The weekly schedule operates when all of the On/Off timer settings have been executed.
Notes:
Any person at the following places cannot be detected.
● Along the wall on which the air conditioner is installed
● Directly under the air conditioner
● Where any obstacle, such as furniture, is between the person and
the air conditioner
A person may not be detected in the following situations.
● Room temperature is high.
● A person wears heavy clothes and his/her skin is not exposed.
● A heating element of which temperature changes signifi cantly is
present.
● Some heat sources, such as a small child or pet, may not be
sensed.
● A heat source does not move for a long time.
The 3D i-see Sensor operates once approximately every 3 minutes
to measure the fl oor temperature and detect persons in the room.
● The intermittent operating sound is a normal sound produced
when the 3D i-see Sensor is moving.
3.7. Ventilation
For LOSSNAY combination
The following 2 patterns of operation is available.
• Run the ventilator together with indoor unit.
• Run the ventilator independently.
Notes: (for wireless remote controller)
Running the ventilator independently is not available.
No indication on the remote controller.
buttons.
buttons.
button, the pattern number settings for the displayed day of the week are deleted.
is on.
.
button to switch between the upper limit
13