8.4.2
Connecting control panel CKA4820
8.4.2.1 SISTORE unit
Siemens Building Technologies
Fire Safety & Security Products
CKA4810 interface configuration
Protocol: SIMATRIX RS232 or SIEMENS IVM
Baud rate: 9600
Parity: None
Fig. 15
SISTORE MX – CKA4820 system overview
For a more detailed description of the connections please refer to Section
MX / MX DVD or Section
7
D escription of SISTORE MX 3G / MX 3G DVD.
1 0 2 H
1 0 3 H
Prerequisite:
The CKA driver is installed and the icon
Section
9 .3
S ubsequent installation of software components.
1 0 4 H
1 0 5 H
1.
Connect the CKA4820 control panel to the SISTORE (see
2.
Configure COM1B on the control panel as an RS485 interface.
Further information on this can be found in the instruction manual for the
control panel.
3.
Start the SISTORE MX application software.
4.
Switch to configuration mode.
5.
Select the System tab.
6.
Mark the checkbox CCTV keyboard. Further information on this can be found
in the SISTORE MX Configuration Manual.
7.
Click Apply.
The interface for the control panel is enabled.
6
D escription of SISTORE
1 0 0 H
1 0 1 H
is displayed in the task bar. See
F ig. 15).
1 0 6 H
Installation
31
02.2009