Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Distances; Fuel Load Sizes And Thermal Output - HASE Jena Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Jena:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

3. Safety Distances

Within a radius of 120 cm in front of and 35 cm
around the stove, flammable, combustible, or heat-
sensitive materials (e.g. furniture, wood or plastic
panelling, curtains, etc.) are not allowed to be loca-
ted in the heat radiating area of the fire box window
(Fig. 1).
With regard to flammable materials beyond the heat
radiating area, a safety distance of 20 cm at the
sides of the stove and 20 cm behind the stove has to
be adhered to (Fig. 1).
WARNING!
Flammable flooring materials (e.g., wood,
laminate, carpeting,) must be protected
with a floorplate made of non-combustible
material (e.g., tiles, safety glass, slate, or
sheet steel).
The size of the floorplate must be larger
than the base of the stove by at least 50
cm in front and at least 19 cm at the sides
of the stove (Fig. 2).
20
35
fig. 1
Dimensions in cm
19
19
floorplate
50
fig. 2
Dimensions in cm

4. Fuel Load Sizes and Thermal Output

The thermal output depends on the amount of fuel
you put in the stove. When adding more fuel, please
do not exceed the maximum fuel load size of 1,7
kg. Exceeding the maximum fuel load size leads to a
danger of overheating, which can result in damage
to the stove and the risk of a stove fire.
NOTE!
To attain a thermal output of approx. 6
kWm, burn wood logs that weigh 1.5 kg
and are no longer than 25 cm in length for
about 45 min. (1.6 kg / 60 min. at brown-
coal briquettes).
The Jena is intended for intermittent operation,
please only apply one fuel layer at a time.
33

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis