Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Alarm Signals - Pepperl+Fuchs NVD-111 Anleitungen

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

WARNING DEVICE NVD-111

Operation

5
5.1
EN
28 - EN
Operation

Alarm Signals

The warning device indicates an alarm status or sensor fault both visually and
acoustically. The respective "OVERFLOW ALARM" or "FAT LAYER ALARM"
LEDs are illuminated until the system returns to a normal status.
LED
Yellow LED "SUPPLY"
Green LED
"SYSTEM OK"
Red LED
"OVERFLOW ALARM"
Red LED
"FAT LAYER ALARM"
Status
Meaning
lights up
The device is connected to the power
supply. The device is in operation.
flashes briefly
Prerequisite DIP switch 1 = ON
In this mode, a brief flash of the "SUPPLY"
LED indicates that a change in status has
been detected by the sensor.
lights up
No errors or alarms active – normal
operation
flashes
No alarm or error active, there was an
alarm or error in the past.
lights up
Alarm active, overflow sensor is covered
with liquid.
flashes
Internal sensor error, lead breakage or
short-circuit
lights up
Alarm active, fat level sensor is covered
with fat.
flashes
Internal sensor error, lead breakage or
short-circuit

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis