WARNING DEVICE NVD-111
Installation
3.1.3
Mounting the FAU-104 Fat Level Sensor
The sensor must be immersed a few centimeters when the liquid is at its normal
level (water zero line).
The exact immersion depth depends on
the type of grease interceptor,
its design
and the height of the maximum fat layer thickness.
The sensor must always be immersed in the liquid. The switching point of the
sensor is located at the same level as the reflectors (see chapter 2.3).
Figure 3.5
1
Fat level sensor FAU-104
A
Air
B
Fat, oil, grease (FOG)
C
Water
L
Water zero line
S
Sensor switching point
X
Alarm limit (maximum fat layer thickness)
A
B
1
C
Mounting the fat level sensor
L
S
EN