• The display is zeroed.
• Decimal point is blinking.
• Leave incremental measurement function by
another simultaneous press of the two arrow
keys
+
. The absolute measuring value is
displayed again.
Precondition: Parameter 'Access:Incremental
measurement function' (_F_rEL) in programming
mode must be programmed to 'on'. Display
MA05 must not be left in programming mode
(see chapter 7 'To leave programming mode').
Calibration / offset value modification
Press the two keys
enter a new value.
Press the two keys
enter an offset value.
The display then shows the calibration / offset
value, which can be changed via the two arrow
keys.
Press key
to store the new value.
If no key has been pressed for approx. 30 s or if
you press again key
display mode.
Precondition: Parameter 'Access: calibration
value modification' (_F_CAL) and/or 'Access:
offset value' (_F_oFF) respectively must be
programmed to 'on'. Display MA05 must not be
left in programming mode (see chapter 7 'To
leave programming mode').
10. Trouble shooting
Error states are recognized and shown in the
display:
Message: Full
Description: display overrun
Action: check parameters and adjust them if
necessary; set display to reference value
Message: display blinking
Description: faulty / no sensor signal
Action: check gap between sensor and ma
gnetic strip
Message / Effect: Decimal point blinking /
MA61 cannot be referenced (calibrated)
Description: Display is still in incremental
measurement function
Action: Leave incremental measurement
function as descriped in chapter 9 or proceed
as follows:
1 4
MA05
+
simultaneously to
+
simultaneously to
, MA05 will return to
Datum 09.01.2002
1. Enter into programming mode
2. Program parameter '_F_rEL' to "ON"
3. Leave programming mode
4. Leave incremental measurement function
as descriped in chapter 9
5. Enter programming mode again
6. Program parameter '_F_rEL' to "OFF"
7. Leave programming mode
Description: Jumping display value
Action: Align sensor accord. to chapter 6.
11. List of commands / service
operation
Parameter:
4800 Baud, no parity, 8 bit, 1
stop bit, no handshake
Data code:
ASCII
Value ranges:
2/3 byte: 0...65535 / 0...± 2
- for data input: both upper and lower case ac-
cepted
-for data output: all reply telegrams are comple-
ted by a CR (=hex13); excepti-
on: command W
Com.
Length Reply
Ax
MSA:
2/9
"xxxxxxx>"
2/9
"xxxxxxx>"
LSA200: 2/13
"xxx...xxx>"
2/9
"xxxxxxx>"
B
1/8
"±xxxxxxx>" absolute value (without
Ey
2/10
"±xxxxxxx>" transmit 3-byte-value
Fy±xxxxxx 9/2
">"
Gy
1/9
"y/xxxxx>"
Art.Nr. 78211
Z.Nr. 8664063
23
Description
unit type / softwareversion
x=0:hardwareversion
x=1:softwareversion
x=0:hardwareversion
x=1:softwareversion
increm. dimension KM,
offset)
y=address (0...5)
xxxxxxx=decimal value
y=0: position value
y=1: zero position value
y=2: calibration value
y=3: offset value
y=4: increm. meas. value
y=5: upper range limit
enter 3-byte-value
y=address (2...5)
xxxxxxx=decimal vlaue
y=2: calibr. value
y=3: offset value
y=4: increm. meas. value
y=5: upper range limit
transmit resolution
y = value (0...8)
xxxxx = text
0/10
10 mm
1/1
1 mm
2/0.1
1/10 mm
3/0.01
1/100 mm
4/1i
1 inch
5/0.1i
1/10 inch
Änd.Stand 389/01