Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel WH Betriebsanleitung Seite 38

Schweißbrenner-system
Vorschau ausblenden Andere Handbücher für WH:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6 Putting into operation
6.7 Connecting the coolant
1
Coolant return hose
Fig. 11
Connecting the coolant
EN - 14
2 Fasten the air-blast hose to the air-blast and spraying unit or the air-blast
valve. Seal the connection gastight if the "Cleaning with compressed air"
option is not used.
WARNING
Risk of burns
The Welding torch system WH/WHPP will become overheated if the coolant
level is too low.
• Wear protective gloves.
• Check the coolant level at regular intervals.
NOTE
• Make sure that the coolant supply and return have been installed
properly. Coolant supply = blue, Coolant return = red
• Do not use any deionized or demineralized water as coolant or for
tightness or flow tests.
This may impair the service life of your welding torch.
• We recommend the use of ABICOR BINZEL series BTC coolant for
liquid-cooled welding torches.
1
2
Re-circulating cooling unit
WH and WHPP
2
3
3
Compressed air hose

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Whpp

Inhaltsverzeichnis