EffECT of MoISTuRE duRING TRANSpoRT ANd SToRAGE
When performing the final inspection of the electrical installation, a "leakage" may be
detected when measuring the Combi Heater's insulation resistance. The reason for this
is that the insulating material of the heating resistors has absorbed moisture from the air
(during storage and/or transport). After operating the heater for a few times, the moisture
will be removed from the resistors.
uSING THE STEAMER
The Combi Heater includes a Steamer NS with a capacity of 5 liters of water. It produces
steam for about 2 hours when filled with 5 liters of water and setting MAX on the external
control unit.
To ensure ideal humidity, the sauna temperature should be between 40 and 50º C, and
the steamer should be left on for about 30 minutes to pre-heat the sauna and produce
sufficient amount of steam before starting bathing.
fILLING THE wATER TANK
Water can be poured through the openings underneath the scent basins or by removing
the steamer cover first (See page 11). The capacity of the tank is 5 liters. If water in the
tank exceeds the 5 liters mark on the level indicator, water from the indicator tube end
might spill on the floor. The water level can easily be monitored through the water level
indicator. If FILL appears on the external control unit's display, cold household tap water
shall be poured through the openings underneath the scent basins by carefully removing
the scent basins.
CAuTIoN: Streamer cover and scent basins are very hot if the heater is in use. Do not
touch them by bare hand. Always before turning on the steamer, make sure that sufficient
amount of water is in the tank.
Low wATER LEVEL
The Combi Heater has a low water detection system which reminds to refill water before
the steamer tank runs dry. To avoid the activation of the low water detection system, refill
water once the water level reaches the REFILL mark on the water level indicator tube
(about 1.5 liter water left in the tank). If no water is refilled at that point, the low water
detection system will automatically turn off the steamer heater at about 1 liter and a FILL
message is displayed together with a buzzer tone on the external control unit. Observe
caution while refilling water as the steamer tank is still hot . After refilling water, the steam
generator heater turns on again after a short while.
If no water is refilled upon the FILL message appears on the display of the control unit,
the steamer will turn on again after a few minutes. The FILL message is repeatedly dis-
played until water is filled in the tank or the unit is turned off. In order to preserve the
heating plate and life span of the combi heater avoid "dry boiling" of the steamer tank.