Speed system not
present [static]
Speed value overflow
or underflow
[dynamic]
Speed system cannot
be sufficiently
determined
[static]
Compatibility error
[static]
Speed system not
present [static]
Speed system cannot
be sufficiently
determined
[static]
Reset with zero index
[static]
Compatibility error
[static]
TIM-EC
Table of errors in speed
Web browser selection set to "determine automatically from
transducer" and the torque transducer is not outputting any
information about the speed system or a speed system is not
present.
Speed value exceeds the maximum value (nominal (rated)
speed + 105%)
Web browser selection set to "determine automatically from
transducer" and the torque transducer is not outputting any
information about the properties Pulses/Rev., Max. Speed,
Type.
Or the selection is set to "Manual" and the maximum speed is
set to 0 or "
".
The stator and rotor speed systems are not compatible in
physics or version.
Table of errors in angle of rotation
Web browser selection set to "determine automatically from
transducer" and the torque transducer is not outputting any
information about the speed system or a speed system is not
present.
Web browser selection set to "determine automatically from
transducer" and the torque transducer is not outputting any
information about the properties Pulses/Rev., Max. Speed,
Type.
Web browser selection set to "determine automatically from
transducer" and reset with zero index is active, but no zero
index present or cannot be determined if present
The stator and rotor speed systems are not compatible in
physics or version.
A3704-4.0 HBM: public