Maintenance

WARNING
Safety instructions
● Before starting work on the machines, make sure that the plant or
system has been disconnected in a manner that is compliant with the
appropriate specifications and regulations.
● In addition to the main currents, make sure that supplementary and
auxiliary circuits, particularly in heating devices, are also
disconnected.
● Certain parts of the machine may reach temperatures above 50 °C.
Physical contact with the machine could result in burn injuries! Check
the temperature of parts before touching them.
● When carrying out cleaning using compressed air, make sure that
appropriate methods of extracting fumes are in place and that
personal protective gear such as gloves, goggles, face masks,
or similar are worn.
● If you are using chemical cleaning agents, observe the instructions
and any warnings provided in the relevant safety data sheet.
Chemical agents must be compatible with the machine's
components, especially if these contain plastics.
Note
Operation characteristics can vary widely. For this reason, only general maintenance
intervals can be specified here.
9.1
Maintenance
9.1.1
Regreasing (optional)
General
As a standard feature, the machines have rolling-contact bearings which are
permanently lubricated with grease (UNIREX N3, made by ESSO). A regreasing
device is possible as an option. In this case, you can find information about
relubrication intervals, quantities and types of grease, and, if required, additional data
on the rating plate or lubricant plate.
Note
Do not mix different types of grease!