Verfügbare Sprachen

Verfügbare Sprachen

Electrical connection
NOTICE
Damage to property
Note the following information to avoid damage to the terminal box.
● Make sure that the components inside the terminal box e.g. terminal board and
cable connections) are not damaged!
● It must be ensured that there are no foreign bodies, dirt or moisture in the
terminal box.
Cable entries into the terminal box according to DIN 42925.
● Close any additional open cable entries with O-rings or suitable flat gaskets, the
terminal box itself must be sealed so that it is dust and water tight using the
original seal.
● Please observe the tightening torques for cable glands and other screws.
● When performing a test run, secure the feather keys without output elements.
Note
The terminal box must be sealed so that dust and water cannot enter.
WARNING
Dangerous voltage
Loosening the safety torx screw can result in death, serious injury or
material damage!
Do not loosen the safety torx screw with respect to the center terminal,
as this ensures a conductive connection between the grounding
conductor and frame!
NOTICE
Serious damage to the machine
Failure to observe these measures will result in serious damage to the machine!
● Do not rotate the terminal box unless the connection cables have not yet been
laid.
● If you release the safety torx screw to both sides of the outer connecting
terminals, this can destroy the machine!
● Remove the three large snap hooks on the terminal board before rotating the
the terminal box. Keep the snap hooks pressed while rotating the terminal box
and use a screwdriver to re-engage when finished.
44