necessary to check any bench marks that have been made and ensure the proper "HI" (Height of
Instrument). After the flashing ADS has been reset, by pressing the button one time, you will have
an additional minute to set and check your measurements.
To turn ADS off press the "B" button once. This will put the instrument into normal Auto
Self-Leveling mode.
CONT
Model LM700-4
UNIT UNLEVEL
This function is prompted through the Auto Level Mode; it clearly
signals the user when the instrument is moved out of level. Turn ADS
on by selecting it in Auto Level Mode and using the MODE button to
return to your desired mode. If ADS is turned on, when the instrument is moved out of level, the
laser head will stop rotating and the beam will blink. The operator must use the right SELECT
button to select the "CONTinue" option.
The default setting for ADS is user selectable. When the instrument is OFF, press and hold the right
SELECT button and then press the ON/OFF button. Once the instrument is on, turn the instrument
off for 15 sec and then back on. This will toggle the default setting for Auto Level Mode between
ADS and on.
Model LM700-3
When the instrument is turned on, the "ADS" function will become active in both Level Mode and
Grade Mode after the unit is on for five minutes. If the unit is moved out of level, and does not
return to the same point of level the instrument will beep and the display will blink "ADS". Press
the "A" button once to acknowledge and reset the "ADS". Changing the speed of the instrument
will turn the "ADS" function off. To turn the "ADS" function back on, the instrument must be shut
off and turned back on.
Grade Mode – Single Axis Grade (Models LM700-GR, & LM700-3)
The single grade function is ideal for general site grading, checking excavations, landscaping and
drainage, and more. (Fig. 9)
The selected grade can be as much as a positive or negative 10%, and set in reference to the Y
axis of the instrument, noted by the embossed printing on the case.
Model LM700-GR
Manual grade mode can be activated by placing the automatic leveling sensor in the OFF position.
NOTE: The ADS must be deactivated to use the Manual Select button.
Pressing the "C" button will deactivate the level sensor. Using the "H" ("MORE") and "I" ("LESS")
arrow buttons, adjust to your desired grade. Rotating head tilts on the Y axis.
NOTE: If the instrument is bumped or moved while in Manual Grade mode, the instrument will not
re-level itself.
The laser will react to "MORE" and "LESS" input. Allow the instrument ample time to react to the
input provided, between grade setups or changes. (Fig. 10)
Model LM700-3
The instrument is in the grade mode when the display shows a grade value.
14 • LM700 SERIES