Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the EYE-18/EYE-36 starts running. During the Reset, the motors
are trimmed and the device is ready for use afterwards.
Stand Alone operation
In the Stand Alone mode, the EYE-18/EYE-36 can be used without controller.
Disconnect the EYE-18/EYE-36 from the controller and call the internal program.
1. Press [MODE/ENTER] button to enter the main menu "MODE" (display flashing)
2. Press [MODE/ENTER] and select "RUN" by pressing [UP] button.
3. Press [MODE/ENTER] and select "AUTO" by pressing [UP] button.
4. Press [MODE/ENTER] and select "ALONE" by pressing [UP] button.
5. Press 3 x [EXIT] to confirm, the display shows "AU-A".
Please refer to the instructions under Control Board, Main functions, menus Run and Edit.
DMX-controlled operation
You can control the projectors individually via your DMX-controller. Every DMX-channel has a different
occupation with different features. The individual channels and their features are listed under DMX-protocol.
Addressing
The Control Board allows you to assign the DMX starting address, which is defined as the first channel from
which the EYE-18/EYE-36 will respond to the controller.
Please, be sure that you don't have any overlapping channels in order to control each EYE-18/EYE-36
correctly and independently from any other fixture on the DMX-chain.
If several EYE-18/EYE-36 are addressed similarly, they will work synchronically.
Press the Up/Down-buttons for setting the desired starting address. Now you can start operating the EYE-
18/EYE-36 via your lighting controller.
Note:
The modes of DMX 512 data and lamp are shown via the display:
International
L
N
33/80
51841300_V_1_2.DOC