Specifi cations (continued)
ARIB Loudness Mode
Target Level:
Scale:
M Integration time:
S Integration Time:
I Silence Gate:
I Relative Gate:
I Tolerance Range:
Over Sensitivity
Over hold time:
OP-59 Loudness Mode
Target Level:
Scale:
M Integration time:
S Integration Time:
I Silence Gate:
I Relative Gate:
I Tolerance Range:
Over Sensitivity
Over hold time:
AGCOM Loudness Mode
Target Level:
Scale:
M Integration time:
S Integration Time:
I Silence Gate:
I Relative Gate:
I Tolerance Range:
Over Sensitivity
Over hold time:
EN-86
9 | Specifi cations
–24 LKFS; adjustable from –10 to –30 LKFS in steps of
0.5 LKFS
ATSC0: 0 .. –60 LKFS
400 ms (SQR)
3 s
–70.0 LKFS
–10.0 LU
±0 LU
–1 dBFS
1 s
–24 LKFS; adjustable from –10 to –30 LKFS in steps of
0.5 LKFS
ATSC0: 0 .. –60 LKFS
400 ms (SQR)
3 s
–70.0 LKFS
–10.0 LU
±2 LU
–2 dBFS
1 s
–24 LKFS; adjustable from –10 to –30 LKFS in steps of
0.5 LKFS
ATSC0: 0 .. –60 LKFS
400 ms (SQR)
3 s
–70.0 LKFS
–8.0 LU
±0.5 LU
–2 dBFS
1 s
Manual | TM3-Primus