Herunterladen Inhalt Inhalt Diese Seite drucken

Lenze Global Drive8200 vector Montageanleitung Seite 159

Frequenzumrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1)
Keypad
PC
Fault
67
System bus (CAN)
ce6
function module on
a
FIF has the
"Warning" or
"BUS−OFF" status
(configurable in
C0126)
68
Communication
ce7
error during remote
a
parameterisation
via system bus
(C0370)
(configurable in
C0126)
91
External fault
EEr
(TRIP−SET)
a
Communication
ErP0
abort between
...
keypad and
standard device
ErP19
a
Fan failure
95
FAn1
(only 8200 motec
a
3 ... 7.5 kW)
TRIP or warning
FAn1
configurable in
C0608
105
Internal fault
H05
a
140
Faulty parameter
id1
identification
a
32
Motor phase error
LP1
(display when
a
C0597 = 1)
182
Motor phase error
LP1
(Display when
C0597 = 2)
EDK82EV222 DE/EN/FR 13.0
Troubleshooting and fault elimination
Cause
CAN controller reports "Warning"
or "BUS−OFF" status
Node does not respond or is not
available
For operation with application
I/O:
Parameter set change−over has
been parameterised incorrectly
A digital signal assigned to the
TRIP−Set function is activated
Various
Fan is defective
Fan is not connected
Motor is not connected
l
Failure of one/several motor
phases
l
Motor current is too low
l
Fault elimination
Fault messages
Remedy
l
Check bus termination
l
Check shield connection of the
cables
l
Check PE connection
l
Check bus load, reduce the baud
rate, if necessary
l
Check bus termination
l
Check shield connection of the
cables
l
Check PE connection
l
Check bus load, reduce the baud
rate, if necessary
The "parameter set change−over"
signal (C0410/13, C0410/14) must be
connected to the same source in all
paramerter sets
Check external encoder
Contact Lenze
Replace fan
Connect fan
Check wiring
Contact Lenze
Connect motor
l
Check motor supply cables
l
Check V
boost,
min
l
Connect motor with a
corresponding power or adapt
motor with C0599
8