Cutout in the control cabinet
8200 vector
E82DV251K2C
E82DV371K2C
E82DV551KxC
E82DV751KxC
Mounting
1.
3.
3.
1.
1. Slide on frame.
2. Insert seal.
3. Slide earthing clamps on the frame with the correct sides:
– The contact springs have to point towards the rear panel of the control cabinet.
– The cutouts of the seal specify the positions.
4. Insert 8200 vector into cutout.
5. Tighten by means of 8 screws M4x10.
– Tightening torque: 1.7 Nm (15 lb−in)
EDK82EV222 DE/EN/FR 13.0
Mounting with thermal separation (push−through technique)
a
1
61
2.
5.
l
Mechanical installation
Dimensions [mm]
b
1
101
161
4.
4
Frame
E82ZJ007V
E82ZJ003
E82DV_001
107