Herunterladen Inhalt Inhalt Diese Seite drucken

EdilKamin MYA Installations-, Betriebs- Und Wartungsanleitung Seite 30

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 82
I
H
g. 7
G
M
g. 9
g. 11
Q
g. 13
R
INSTALLATION
I
L
L1
g. 8
N
P
g. 10
g. 12
S
Fitting the top ue pipe outlet kit
(FOR ALL VERSIONS)
- Remove the diaphragm (H - g. 7) and, if necessary the per-
forated lower rear panel as well (I - g. 7).
- Slacken the clamp (L - g. 8) and remove the outlet ue pipe
(L1 - g. 8).
- Position the inspection elbow (M - g. 9) and x it using the
clamp slackened previously.
- Remove the cast iron cap (N - g. 10) resting on the top and
t the ue pipe outlet (P - g. 10) from the side of the stove.
- Position the two plating closers (Q - g. 11) around the ue
pipe outlet and x them using the screws.
- Fit the side removed previously (for the version with glass
sides, put the gaskets and small parts back in place as shown in
gure 12).
- Fit the ue pipe (R - g. 13) (not supplied) over the outlet and
x it using the clamp (S - g. 13) (not supplied).
- 30
-

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis