Press the » OK « key to start the selected function.
Display:
Use the » ▼ « key to select "Confirm"
and then press the » OK « key.
–
Fresh air calibration is now executed.
The sensitivity of the EC O
zero point of all other sensors is set to 0.
After completion of fresh air calibration:
Display:
Press the » OK « key to terminate the
function.
Press and hold the » ▲ « key until "Exit Quick Menu" is displayed.
Press the » OK « key to return to measuring mode.
5
Storage
Dräger recommends storing the instrument in charging mode
(see "Charging / changing the power pack" on page 49).
Dräger recommends checking the charge status of the power
supply at least every 3 weeks if the device is not being stored in
charging mode.
The sensors are supplied with power even when the instrument is
switched off to ensure a faster warm-up time when switching on.
The power pack also loses charge due to extended periods of storage
without use. For this reason, the instrument should be kept
permanently on charge.
If the instrument is stored without charge, a full charge should be
carried out:
–
every 3 weeks (NiMH power pack 3.0 Ah)
–
every 5 weeks (NiMH power pack 6.0 Ah)
.
Dräger X-am 7000
Fresh air cal.
back
starting Fresch air
calibration
Confirm
sensor is set to 20.9 Vol.% and the
2
Fresh air cal.
back
IR-CO
: ok
2
CA-CH
: ok
4
EC-CO
: ok
EC-H
S
: ok
2
EC-O
: ok
2
6
Disposal
1/3
This product must not be disposed of as household waste.
This is indicated by the adjacent icon.
You can return this product to Dräger free of charge.
For information please contact the national marketing
organisations and Dräger.
It is not permitted for batteries to be disposed of without
3/3
household waste. This is indicated by the adjacent icon.
Collect and dispose of batteries and rechargeable batteries at
battery collection centres, in accordance with applicable
regulations.
Storage