formed by skilled and qualified personnel.
S
Keep these instructions carefully for future reference.
Introduction
The dehumidifiers of the series KRS were conceived and designed to operate in environments containing chlorine, such as
swimming pools, rooms with hydromassage and small saunas. These dehumidifiers are equipped with a sophisticated elec-
tronic Board that handles all the different operations of the machine: using the control panel you can easily set the operating
parameters.
When the room temperature is below 16° C ice can form on the evaporator: the electronic Board authomatically detects it and
performs a defrost cycle, eliminating it when necessary.
For a correct operation of the appliance it is necessary to observe the installation instructions below.
Positioning
A
>500
Installation
For a correct installation, follow the sequence of operations described below.
Transporting and handling
Before installation it is advisable to bring the packed machine as close as possible to the place where it will be mounted.
!
Caution: the size and weight of the machine require using means such as pallet trucks and trolleys for
handling. Never lift the machine by yourself.
Wall bracket installation
Use the supplied bracket as a template to mark the holes on the wall as shown in pic. 4.
!
Make sure that the wall is capable of supporting the appliance in working condition.
gb-42
Pic.2 – Positioning
B
C
>1000
>100
Tab.2 – Minimum distances
D
E
>500
>2000